These lintels are designed to take direct imposed loads.
Rafters, wall plates and floor joists may be accommodated
as directly imposed loads – see tables for loadbearing capacities.
BEARING: Minimum of 150mm each side or as directed by the
structural engineer.
PROPPING: Propping is not required with this type of lintel.
BRICKWORK: Non-composite lintels do not require brickwork bonded
to them. Point loads from girders, trusses, steel beams ect. require to be
referred to our Customer Advisory Service.
POSITIONING: Lintels must be placed with wire in correct position.
Lintels are marked top.